1.
Lancet Infect Dis ; 22(12): 1716-1727, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2008205

ABSTRACT

BACKGROUND: The Valneva COVID-19 vaccine (VLA2001; Valneva Austria, Vienna, Austria) is an inactivated whole-virus, adjuvanted SARS-CoV-2 vaccine. We aimed to assess the safety and immunogenicity of primary vaccination with VLA2001 versus the ChAdOx1-S (Oxford-AstraZeneca) adenoviral-vectored vaccine. METHODS: In this immunobridging phase 3 trial (COV-COMPARE), participants aged 18 years and older who were medically stable (as determined by an investigator) were enrolled at 26 sites in the UK. In the double-blind, randomised, controlled arm of the trial, participants aged 30 years and older were randomly assigned (2:1) to receive two doses of VLA2001 (0·5 mL; with 33 antigen units [AU] per dose) or ChAdOx1-S (0·5 mL; with 2·5 × 108 infectious units per dose) on days 1 and 29. In another arm, participants aged 18-29 years received two doses of VLA2001 (same dose) open label on days 1 and 29. The primary immunogenicity outcome was the immune response of a two-dose schedule of VLA2001 on day 43, in adults aged 30 years and older, versus two doses of ChAdOx1-S via superiority of geometric mean titres (GMTs) of neutralising antibodies (GMT ratio of >1 at a two-sided significance level of 5%) and non-inferiority of the seroconversion rate (non-inferiority margin of -10% for the lower limit of the 95% CI for the difference between groups). The primary safety outcome was the frequency and severity of any adverse events in all participants up to day 43. Safety was assessed in all participants who received at least one dose of vaccine. GMTs were assessed in a subset of participants aged 30 years and older who were seronegative at baseline, had at least one evaluable antibody titre measurement after vaccination, and had no confirmed COVID-19 during the study (immunogenicity population); and seroconversion was assessed in the per-protocol population, which comprised the immunogenicity population but excluding any participants with major protocol violations. For each timepoint, only participants with available data were included in the analysis. This study is registered with ClinicalTrials.gov, NCT04864561, and is ongoing. FINDINGS: Between April 28 and June 3, 2021, 4181 individuals were screened and 4017 enrolled, of whom 2975 (74%) were aged 30 years or older and randomly assigned to receive VLA2001 (n=1978) or ChAdOx1-S (n=997), and 1042 (26%) were aged 18-29 years (all received open-label VLA2001). 4012 participants received at least one dose of vaccine (1040 in the open-label VLA2001 group, 1977 in the randomised VLA2001 group, and 995 in the ChAdOx1-S group). The immunogenicity population comprised 492 participants in the randomised VLA2001 group and 498 in the ChAdOx1-S group; three participants in the VLA2001 group were excluded from the per-protocol population. VLA2001 induced higher neutralising GMTs than did ChAdOx1-S (803·5 [95% CI 748·5-862·6] vs 576·6 [543·6-611·7]; GMT ratio 1·39 [95% CI 1·25-1·56]; p<0·0001), and non-inferior seroconversion rates (444 [97·4%] of 456 participants vs 444 [98·9%] of 449; difference -1·5% [95% CI -3·3 to 0·2]. Any adverse event was reported in 963 (92·6%) participants in the open-label VLA2001 group, 1755 (88·8%) in the randomised VLA2001 group, and 976 (98·1%) in the ChAdOx1-S group. Most adverse events reported were mild or moderate in severity. INTERPRETATION: VLA2001 has a favourable tolerability profile and met superiority criteria for neutralising antibodies and non-inferiority criterion for seroconversion rates compared with ChAdOx1-S. The data presented here formed the basis of successful marketing approval for use of VLA2001 in primary vaccination in the EU, the UK, Bahrain, and United Arab Emirates. FUNDING: UK Department of Health and Social Care and Valneva Austria.


Subject(s)
COVID-19 Vaccines , COVID-19 , Viral Vaccines , Adult , Humans , Adenoviridae/genetics , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/prevention & control , COVID-19 Vaccines/adverse effects , Double-Blind Method , Immunogenicity, Vaccine , SARS-CoV-2 , United Kingdom
2.
J Infect ; 85(3): 306-317, 2022 09.
Article in English | MEDLINE | ID: covidwho-1895207

ABSTRACT

OBJECTIVES: We aimed to evaluate the safety and optimal dose of a novel inactivated whole-virus adjuvanted vaccine against SARS-CoV-2: VLA2001. METHODS: We conducted an open-label, dose-escalation study followed by a double-blind randomized trial using low, medium and high doses of VLA2001 (1:1:1). The primary safety outcome was the frequency and severity of solicited local and systemic reactions within 7 days after vaccination. The primary immunogenicity outcome was the geometric mean titre (GMT) of neutralizing antibodies against SARS-CoV-2 two weeks after the second vaccination. The study is registered as NCT04671017. RESULTS: Between December 16, 2020, and June 3, 2021, 153 healthy adults aged 18-55 years were recruited in the UK. Overall, 81.7% of the participants reported a solicited AE, with injection site tenderness (58.2%) and headache (46.4%) being the most frequent. Only 2 participants reported a severe solicited event. Up to day 106, 131 (85.6%) participants had reported any AE. All observed incidents were transient and non-life threatening in nature. Immunogenicity measured at 2 weeks after completion of the two-dose priming schedule, showed significantly higher GMTs of SARS-CoV-2 neutralizing antibody titres in the highest dose group (GMT 545.6; 95% CI: 428.1, 695.4) which were similar to a panel of convalescent sera (GMT 526.9; 95% CI: 336.5, 825.1). Seroconversion rates of neutralizing antibodies were also significantly higher in the high-dose group (>90%) compared to the other dose groups. In the high dose group, antigen-specific IFN-γ expressing T-cells reactive against the S, M and N proteins were observed in 76, 36 and 49%, respectively. CONCLUSIONS: VLA2001 was well tolerated in all tested dose groups, and no safety signal of concern was identified. The highest dose group showed statistically significantly stronger immunogenicity with similar tolerability and safety, and was selected for phase 3 clinical development.


Subject(s)
COVID-19 Vaccines , COVID-19 , Adult , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/prevention & control , COVID-19/therapy , COVID-19 Vaccines/adverse effects , Double-Blind Method , Humans , Immunization, Passive , Immunogenicity, Vaccine , SARS-CoV-2 , COVID-19 Serotherapy